Cable 2X16Awg Blindado Instrumentacion Bobina 305Mt
Producto BELDEN con SKU 1030A 0101000. Familia de catálogo: 1030A. Referencia en inglés: 1030A – Inst, 1 Pr #16 Str BC, PVC Ins E1, OS, Blk PVC Jkt, 300V PLTC, ITC, CMG. Descripción del fabricante: UL Instrumentation, 1 Pair 16AWG (7×24) Bare Copper, PVC Insulation E1 Color Code, Overall Beldfoil® Shield, Black PVC Outer Jacket, PLTC ITC CMG SUN RES.
Datos del producto
- Código de color: 010
- Color: NEGRO
- Peso: 43.9 kg
- Color del fabricante: Black
- Presentación: Reel
- Longitud: 1,000 ft
Especificaciones técnicas
Product Overview
- Suitable Applications:: Industrial Control, Raceways Cable trays and ducts, Digital Control, Instruments (4-20ma, 0-10v, …),low voltage digital control (24v, …), encoders, control circuits, distributed control system (DCS),programmable logic controller (PLC), Solenoids, Valves, Actuators, Positioners
Construction Details
- Element: Pair(s)
- No. of Elements: 1
- Size: 16 AWG
- Stranding: 7×20
- Material: BC – Bare Copper
- Material: PVC – Polyvinyl Chloride
- Nom. Thickness: 0.017 in (0.43 mm)
- Nom. Insulation Diameter: 0.091 in (2.3 mm)
- Color Code: ICEA Chart E1
- Shield Type: Tape
- Material: Bi-Laminate (Alum+Poly)
- Coverage: 100%
- Drainwire Type: 18 AWG (7×26) TC
- Nom. Thickness: 0.037 in (0.94 mm)
- Nom. Diameter: 0.259 in (6.58 mm)
- Ripcord: Yes
- Overall Cable Diameter (Nominal):: 0.259 in (6.58 mm)
Electrical Characteristics
- Element: Pair(s)
- Nom. Conductor DCR: 4.2 Ohm/1000ft (14 Ohm/km)
- Nom. Capacitance Cond-to-Cond: 61 pF/ft (200 pF/m)
- Nom. Capacitance Cond-to-Other (Conds + Shield): 114 pF/ft (374 pF/m)
- Nom. Inductance: 0.190 µH/ft (0.623 µH/m)
- Max. Current: 18 Amps per conductor @ 30°C
- Nom Outer Shield DCR:: 5.68 Ohm/1000ft (18.6 Ohm/km)
- UL Voltage Rating: 300 V (PLTC, CMG, AWM 2464), 150 V (ITC)
Mechanical Characteristics
- UL Temperature: 105°C
- Operating: -30°C to +105°C
- Stationary Min.: 3.1 in (79 mm)
- Installation Min.: 3.1 in (79 mm)
- Max. Pull Tension:: 94 lbs (43 kg)
- Bulk Cable Weight:: 40 lbs/1000ft (60 kg/km)
Standards and Compliance
- Environmental Suitability:: Indoor/Outdoor, Indoor, Outdoor, Sunlight Resistance
- Flammability / Reaction to Fire:: UL 1685 FT4 Loading, FT4, IEEE 1202 FT4
- NEC / UL Compliance:: Article 725, Article 727, Article 800, CMG, ITC, PLTC, CL3
- AWM Compliance:: AWM 2464
- CEC / C(UL) Compliance:: CMG
- European Directive Compliance:: EU CE Mark, EU Directive 2015/863/EU (RoHS 2 amendment), EU Directive 2011/65/EU (RoHS 2), EU Directive 2012/19/EU (WEEE)
- APAC Compliance:: China RoHS II (GB/T 26572-2011)
History
- Update and Revision:: Revision Number: 0.719 Revision Date: 04-13-2026
Part Numbers
- Footnote:: C – CRATE REEL PUT-UP., Z – FINAL PUT-UP MAY VARY (= OR -) 10% FOR SPOOLS OR REELS AND (+ OR -) 5% FOR UNREEL CARTONS FROM LENGTH SHOWN.